Number of cables: 1

Channel width: 0,97m

Channel depth: 5,6m

Useful width of chassis: 400mm

Chassis length: 7500mm

STEP OUARDANINE

Number of cables: 1

Channel width: 0,6m

Channel depth: 2,53m

Useful width of chassis: 400mm

Chassis length: 6365mm

STEP EL JEM

Number of cables: 1

Channel width: 0,7m

Channel depth: 3,21m

Useful width of chassis: 500mm

Chassis length: 6945mm

STEP TRIVIÈRES

Number of cables: 3

Channel width: 2,7m

Channel depth: 9,1m

Useful width of chassis: 1800mm

Chassis length: 12988mm

STEP DE TEMPLEUVE

Number of cables: 1

Channel width: 0,6m

Channel depth: 6,4m

Useful width of chassis: 400mm

Chassis length: 3619mm

AQUIRIS

Number of cables: 3

Channel width: 1,5m

Channel depth: 7,5m

Useful width of chassis: 1300mm

Chassis length: 11388mm

STEP DE CASTEAU

Number of cables: 1

Channel width: 0,6m

Channel depth: 2,51m

Useful width of chassis: 400mm

Chassis length: 6253mm

STEP DE WATTRELOS

Screen 1

Number of cables: 3

Channel width: 2,2m

Channel depth: 4,8m

Useful width of chassis: 2000mm

Chassis length: 8683mm

Screen 2

Number of cables: 3

Channel width: 2,5m

Channel depth: 6,1m

Useful width of chassis: 2875mm

Chassis length: 9975mm

STEP EL YAMAMA

Number of cables: 3

Channel width: 1,4m

Channel depth: 5,5m

Useful width of chassis: 1200mm

Chassis length: 9388mm

STEP RAOUED

Number of cables: 3

Channel width: 1,4m

Channel depth: 7,4m

Useful width of chassis: 1200mm

Chassis length: 11288mm

SP THIRIAU DU LUC

Number of cables: 3

Channel width: 1,53m

Channel depth: 4,17m

Useful width of chassis: 1300mm

Chassis length: 8158mm

SP SCAILMONT

Number of cables: 3

Channel width: 1,99m

Channel depth: 5,3m

Useful width of chassis: 1800mm

Chassis length: 9088mm

SP RIVAGE - ARRIERE

Number of cables: 3

Channel width: 1,98m

Channel depth: 2,225m

Useful width of chassis: 1980mm

Chassis length: 6388mm

SP RIVAGE - AVANT

Number of cables: 3

Channel width: 1,02m

Channel depth: 2,45m

Useful width of chassis: 800mm

Chassis length: 6338mm

STATION DE POMPAGE DKHILA

Number of cables: 3

Channel width: 1,55m

Channel depth: 4,2m

Useful width of chassis: 1300mm

Chassis length: 8088mm

STATION DE POMPAGE M6

Number of cables: 3

Channel width: 1,55m

Channel depth: 3,8m

Useful width of chassis: 1300mm

Chassis length: 7688mm

STATION DE POMPAGE DE BORJ AMRI

Number of cables: 3

Channel width: 1,5m

Channel depth: 4,6m

Useful width of chassis: 1300mm

Chassis length: 8488mm

STATION DE POMPAGE DE MORNAGUIA SP2

Number of cables: 3

Channel width: 1m

Channel depth: 6,2m

Useful width of chassis: 800mm

Chassis length: 10088mm

STATION DE POMPAGE DE MORNAGUIA SP1

Number of cables: 3

Channel width: 1m

Channel depth: 5m

Useful width of chassis: 800mm

Chassis length: 8888mm

COLLECTEURS DE MAURAGE

Number of cables: 1

Channel width: 1m

Channel depth: 10,17m

Useful width of chassis: 600mm

Chassis length: 13939mm

STATION DE POMPAGE DE EL FEJJA

Number of cables: 3

Channel width: 1m

Channel depth: 2,5m

Useful width of chassis: 800mm

Chassis length: 6388mm

WESTVLEES WESTROZEBEKE

Number of cables: 1

Channel width: 0,8m

Channel depth: 2,29m

Useful width of chassis: 500mm

Chassis length: 5669mm

SP EL GHDIR MONASTIR

Screen 1

Number of cables: 3

Channel width: 1m

Channel depth: 2,8m

Useful width of chassis: 800mm

Chassis length: 6688mm

Screen 2

Number of cables: 3

Channel width: 0,8m

Channel depth: 3,8m

Useful width of chassis: 600mm

Chassis length: 7688mm

STEP DE WONCK

Number of ribbons: 1

Channel width: 0,7m

Channel depth: 1,62m

Useful width of chassis: 500mm

Chassis length: 13853mm

FOND DE COUVENAILLE

Number of ribbons: 1

Channel width: 0,7m

Channel depth: 1,45m

Useful width of chassis: 500mm

Chassis length: 4857mm

STEP DE FLEURJOUX

Number of cables: 1

Channel width: 0,6m

Channel depth: 5,3m

Useful width of chassis: 400mm

Chassis length: 9224mm

STEP DE WELKENRAEDT

Number of cables: 1

Channel width: 1m

Channel depth: 10,5m

Useful width of chassis: 600mm

Chassis length: 13601mm

RWZI BRASSCHAAT

Number of cables: 2

Channel width: 2,91m

Channel depth: 4,46m

Useful width of chassis: 2700mm

Chassis length: 9012mm

STEP DE HAMME MILLE

Number of cables: 1 

Channel width: 1m

Channel depth: 9,6m

Useful width of chassis: 800mm

Chassis length:13610mm

MORNIMONT

Screen 1

Number of cables: 1 

Channel width: 1,3m

Channel depth: 11,03m

Useful width of chassis: 800mm

Chassis length:14315mm

Screen 2

Number of cables: 1 

Channel width: 1m

Channel depth: 7,61m

Useful width of chassis: 800mm

Chassis length:10895mm

HERMALLE SOUS ARGENTEAU

Number of cables: 1 

Channel width: 1,2m

Channel depth: 15,6m

Useful width of chassis: 1000mm

Chassis length:18885mm

STEP DE GEMBLOUX

Number of cables: 2

Channel width: 1,41m

Channel depth: 7,15m

Useful width of chassis: 1250mm

Chassis length:10335mm

STATION DE POMPAGE DE TERTRE EST

Screen 1

Number of cables: 2

Channel width: 2,6m

Channel depth: 6,455m

Useful width of chassis: 2400mm

Chassis length:11699mm

Screen 2 and 3

Number of cables: 2

Channel width: 3,3m

Channel depth: 6,455m

Useful width of chassis: 1400mm

Chassis length:11699mm

STATION DE POMPAGE DE TERTRE OUEST

Screen 1

Number of cables: 2

Channel width: 1,3m

Channel depth: 6,36m

Useful width of chassis: 1100mm

Chassis length: 11499mm

Screens 2 and 3

Number of cables: 2

Channel width: 4,3m

Channel depth: 6,36m

Useful width of chassis: 1900mm

Chassis length: 11499mm

STATION D'EPURATION DE CHIEVRES

Number of cables: 1

Channel width: 1m

Channel depth: 4,55m

Useful width of chassis: 500mm

Chassis length: 8755mm

STATION D'EPURATION DE FES

 Screens 1 to 8

Number of cables: 2

Channel width: 1,5m

Channel depth: 1,97m

Useful width of chassis 1300mm

Chassis length: 4649mm

STEP DE LE ROEULX

Number of cables: 1

Channel width: 1m

Channel depth: 1,45m

Useful width of chassis: 500mm

Chassis length: 4318mm

STEP DE GAURAIN-RAMECROIX

Number of cables: 1

Channel width: 1m

Channel depth: 5,6m

Useful width of chassis: 500mm

Chassis length: 9383mm

STATION D'EPURATION DE SIRAULT

Number of cabless: 1

Channel width: 1m

Channel depth: 0,97m

Useful width of chassis: 500mm

Chassis length: 3835mm

STEP DE SAINT AUBIN

Number of cables: 1

Channel width: 2m

Channel depth: 4,7m

Useful width of chassis: 500mm

Chassis length: 7150mm

STEP DE WIERS

Number of cables: 1

Channel width: 1m

Channel depth: 6,25m

Useful width of chassis: 800mm

Chassis length: 9892mm

STATION D'ÉPURATION DE FELUY

Number of cables: 1

Channel width: 1,5m

Channel depth: 8,219m

Useful width of chassis: 800mm

Chassis length: 11950mm

GALLOO

Number of cables: 1

Channel width: 1,511m

Channel depth: 2,94m

Useful width of chassis: 1000mm

Chassis length: 6226mm

STATION D'ÉPURATION DE HERVE

Number of cables: 2

Channel width: 1,6m

Channel depth: 1,6m

Useful width of chassis: 1400mm

Chassis length: 5273mm

STATION D'ÉPURATION DE HAVRE

Number of cables: 1

Channel width: 1,2m

Channel depth: 8,534m

Useful width of chassis: 1000mm

Chassis length: 12548mm

COMMUNE DE MANAGE-COLLECTEUR DE LA SAMME

Number of cables: 1

Channel width: 0,8m

Channel depth: 5,292m

Useful width of chassis: 600mm

Chassis length: 8872mm

STATION DE POMPAGE DE SETIF OUEST

Number of cables: 2

Channel width: 2,5m

Channel depth: 9,965m

Useful width of chassis: 2300mm

Chassis length: 14053mm

STATION DE POMPAGE DES BLANCS TRIEUX ANDERLEUS

Number of cables: 1

Channel width: 0,671m

Channel depth: 5,217m

Useful width of chassis: 500mm

Chassis length: 5980mm

CHAPELLE-LEZ-HERLAIMONT

Number of cables: 1

Channel width: 0,6m

Channel depth: 4,2m

Useful width of chassis: 400mm

Chassis length: 7808mm

SP TAMINES

Number of cables: 1

Channel width: 1m

Channel depth: 3,452m

Useful width of chassis: 800mm

Chassis length: 7342mm

SP AUTOROUTE

Number of cables: 1

Channel width: 0,75m

Channel depth: 7,836m

Useful width of chassis: 500mm

Chassis length: 11805mm

Andere referenties
ARCHIMEDEAN SCREW PUMPS
CABLE SCREENS
CHAIN SCREENS
STEP SCREENS
AVIETA VINALMONT
At Dewekon Engineering, the costumer comes first
Dewekon Engineering stands for quality
Dewekon Engineering strong in installations for water treatment
© Dewekon 2022 | Disclaimer | Privacy statement | Cookie statement | site by plenso
© Dewekon 2022 | Disclaimer | Privacy | Cookie | Plenso

Wij maken gebruik van cookies

De website van Dewekon maakt gebruik van cookies om uw surfervaring te verbeteren. Door het verder gebruiken van deze website, gaat u hier expliciet mee akkoord.

Ik snap het! Meer informatie